TransAct Technologies ITHERM 280 User Manual
Page 215

iTherm
®
280 Programmer’s Guide
Programming Codes
28-07764
Rev C
Page 213
Bit
Off/On
Hex
Decimal
Status
0
Off
00H
<0>
Drawer kick-out connector pin 3 low
On
01H
<1>
Drawer kick-out connector pin 3 high
1-3
-
-
-
Undefined
4
Off
00H
<0>
Not used; fixed to Off
5,6
-
-
-
Undefined
7
Off
00H
<0>
Not used; fixed to Off
Table 34 Drawer Kick-out Connector Status (
Function
Transmit Real-Time Status
ASCII
[DLE] [EOT]
Hexadecimal 10H 04H
Decimal
<16> <4>
Range
1
≤
n
≤
4
Description The [DLE] EOT
command is executed if the printer is off line, the print buffer is full, or an error
occurs. If the printer goes off line due to a paper-end condition, bit 5 of the
printer status (waiting for on-line recovery) is on from the time the paper roll is
inserted to the time the printer goes on-line. See the [GS] z 0 command for
details of the on-line recovery wait time. The paper roll low sensor is an option.
If the printer does not have a paper low sensor, bits 2 and 3 of the paper roll
sensor status will always be “Paper adequate.” Bit 3 of the second byte is always
“No error occurred.”
Function
1
Transmit printer status
2
Transmit off line status
3
Transmit error status
4
Transmit paper roll sensor status
Table 35 Values for the Status Function,
Bit
Off/On
Hexl
Decimal
Status
0
Off
00H
<0>
Not used; fixed to off
1
On
02H
<2>
Not used; fixed to on
2
Off
00H
<0>
Drawer kick-out connector pin 3 low
On
04H
<4>
Drawer kick out connector pin 3 high
3
Off
00H
<0>
On-line
On
08H
<8>
Off line
4
On
10H
<16>
Not used; fixed to on
5
-
-
-
Undefined
6
-
-
-
Undefined
7
Off
00H
<0>
Not used; fixed to off
Table 36 Printer Status (