Data ports, Interfaces and sockets – codec 6000 mxp – TANDBERG 6000MXP User Manual
Page 37
37
D 13887.08
MAY 2008
TANDBERG 3000
MXP
&
6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Interfaces and Sockets – Codec 6000
MXP
Data Ports
uSB interface.
For future use.
Data Ports
Data port 1
Data port 2
Pin
Signal name
Direction
Signal name
Direction
1
Carrier detect,
CD
From DCE
Carrier detect,
CD
From DCE
2
Receive data,
RXD
From DCE
Receive data,
RXD
From DCE
3
Transmit data,
TXD
To DCE
Transmit data,
TXD
To DCE
4
1
Data terminal
ready, DTR
From DCE
12 V / 1 A
5
Signal GND
Signal GND
6
Data set ready,
DSR
From DCE
Data set ready,
DSR
From DCE
7
Ready to send,
RTS
To DCE
Ready to send,
RTS
To DCE
8
Clear to send,
CTS
From DCE
Clear to send,
CTS
From DCE
9
Ring indicator,
RI
From DCE
Ring indicator,
RI
From DCE
1) The TANDBERG main camera is normally connected to data port 2 and pin No. 4
provides 12 V
dc
/ 1 A to the main camera. Otherwise the pin-outs are the same for the
two data ports.
Data port 1 (upper) and 2 (lower).
The Data ports
are implemented as Digital Circuit Terminating
Equipment (DCE).
NoTe!
The TANDBERG main camera is normally
connected to data port 2 and pin No. 4 provides
12 V
dc
/ 1 A to the main camera. Otherwise the pin-
outs are the same for the two data ports.
9-pin D-SuB pin-out
External view of socket
6
9
1
5