Communicating with the Video Switch

Configuration Commands

Messages starting with 8x-01-40-<00..1f> are configuration commands.

Command

Command Packet

Comments

SW_Port_0_Cfg

8x 01 40 00 ... ff

Currently not in use.

SW_Port_1_Cfg

8x 01 40 01 ... ff

Currently not in use.

SW_Port_2_Cfg

8x 01 40 02 0p ff

p=0: Disable this port
p=1: Enable this port as a secondary
VISCA chain port for cameras usually con-
nected to codec input 2-5 (default).
p=2: Use this port as a debug port.

SW_Port_3_Cfg

8x 01 40 03 0p ff

p=0: Disable this port
p=1: Enable this port as a dual visca port
(default).
p=2: Use this port as a debug port.

SW_Port_x_
Push_Cfg

8x 01 40 04 0p
0q 0r ff

Configure which push messages to send
for given port.
p=0/3: Configure port 0 or 3.
qr bit 0: Enable/disable SW_Input_Push.
qr bit 1: Enable/disable SW_Sync_Push.
qr bit 2: Enable/disable Enhanced VISCA.
qr = 00 is default for both ports.

Switch control commands

Messages starting with 8x-01-40-<20..3f> are switch control commands.

Command

Set

Command Packet

Comments

SW_Input_Set

8x 01 40 20 0p ff

Sets which input to use.
p=0..5
This will generate a SW_Input_Push on
the THSI Visca port if issued from the
dual visca port and vice versa.

Misc.

Command

Command Packet

Comments

CAM_Boot

8x 01 42 ff

Reboot the switch. This will also reset se-
rial speed to 9600.

Inquiries

Messages starting with 8x- 09...

Command set

Command Packet

Reply and comments

CAM_ID_Inq

8x 09 04 22 FF

Reply: 90 50 zz xx 00 yy FF
zz xx = switch rev, zz=0x40 for TVS
yy = firmware rev

CAM_SWID_Inq

8x 09 04 23 ff

Reply: x0 50 [1-125 bytes SWID] ff.

SW_Input_Inq

8x 09 40 20 ff

Reply 90 50 0p ff
p=Active input, 0..5

SW_Sync_Inq

8x 09 40 e0 0p ff

Input: p=Input 0..5
Reply: 90 50 0p ff
p=2: Input has sync
p=3: No sync on input

SW_InputFor-
mat_ Inq

8x 09 40 e1 ff

Reply: 90 50 0p 0q ff
pq = Format for active input.
0 = 720p60
1 = 720p59.94
2 = 720p50

Push Messages

Command set

Push Message

Comments

SW_Input_Push

x0 01 40 20 0p ff

The input has been changed.
p = the new input source

SW_Sync_Push

x0 01 40 e0 0p
0q ff

Sync state has changed on an input.
This one will also be sent if the format is
changed, so if sync is on, send a SW_For-
mat_Inq.
p = source 0..5
q = state: 2 = sync, 3 = no sync