TANDBERG 6000MXP User Manual
Page 201
201
TANDBERG 3000
MXP
&
6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Status Information – xstatus /xstatus.xml
D 13887.08
MAY 2008
Status information followed by a
*
will not be shown unless Detailed Level has been set to 2
–
see
XACLI – Special commands – xpreferences
PRI
(ready =
True / False
)
If ready =
False
the following will be included:
Layer1Alarm:
RedAlarm / YellowAlarm / BlueAlarm
Example:
*s PRI (ready=False):
Layer1Alarm: RedAlarm
*s/end
If ready =
True
the following will be included:
Channel [1..24/31]
(type =
BChannel / DChannel
status =
NA / Idle / Calling / Answering / Proceeding / Connect / Disconnecting / Disconnected
)
If type =
DChannel
and status =
NA
the following will be included:
If type =
BChannel / DChannel
and status =
Idle
the following will be included:
If type =
BChannel
and status =
Calling / Answering / Proceeding / Connect
the following will be included:
CallingNumber:
ConnectionTime:
If type =
BChannel
and status =
Disconnecting / Disconnected
the following will be included:
CallingNumber
CauseLocation
ChannelCause
ConnectionTime
PRI