beautypg.com

G703 – TANDBERG 6000MXP User Manual

Page 197

background image

197

TANDBERG 3000

MXP

&

6000

MXP

REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Status Information – xstatus /xstatus.xml

D 13887.08
MAY 2008

Status information followed by a

*

will not be shown unless Detailed Level has been set to 2

see

XACLI – Special commands – xpreferences

G703

(ready =

True / False

)

If ready =

False

the following will be included:

Layer1Alarm:

RedAlarm / YellowAlarm / BlueAlarm

If ready =

True

the following will be included:

Channel [1..24 / 31]

(status =

NA / Idle / Calling / Answering / Proceeding / Connect / Disconnecting / Disconnected

)

If status =

NA / Idle

the following will be included:

If status =

Calling / Answering / Proceeding / Connect

the following will be included:

CallingNumber:

ConnectionTime:

If status =

Disconnecting/Disconnected

the following will be included:

CallingNumber:

CauseLocation:

ChannelCause:

ConnectionTime:

Example:

G703