Basic programming, 2 range/printing range, Range no. tables – Omega RD200 User Manual

Page 46

background image

-42-

8.

BASIC PROGRAMMING

8.2 Range/Printing Range

4

Range No. Tables

1) Voltage input

№ Input type

Measuring range

Remarks

01 -13.80

to

13.80

mV

02 -27.60

to

27.60

mV

03 -69.00

to

69.00

mV

04 -200.0

to

200.0

mV

05

DC

(mV)

-500.0 to 500.0

mV

06 -2.000

to

2.000

V

07 -5.000

to

5.000

V

08 -10.00

to

10.00

V

09 -20.00

to

20.00

V

10

DC

(V)

-50.00 to 50.00

V

For current

input, see

Item 16.2.


2) Thermocouple input (*1)

Measuring range

No.

Input

type

°C

°F

21

-200.0 to 300.0

-320.0 to 570.0

22

-200.0 to 600.0

-320 to 1110

23

K

-200 to 1370

-320 to 2490

24

-200.0 to 200.0

-320.0 to 390.0

25

-200.0 to 350.0

-320.0 to 660.0

26

E

-200 to 900

-320 to 1650

27

-200.0 to 250.0

-320.0 to 480.0

28

-200.0 to 500.0

-320.0 to 930.0

29

J

-200 to 1200

-320 to 2190

30

-200.0 to 250.0

-320.0 to 480.0

31

T

-200.0 to 400.0

-320.0 to 750.0

32

0 to 1200

32 to 2190

33

R

0 to 1760

32 to 3200

34

0 to 1300

32 to 2370

35

S

0 to 1760

32 to 3200

36

B

0 to 1820

32 to 3300

37

-200.0 to 400.0

-320.0 to 750.0

38

-200.0 to 750.0

-320 to 1380

39

N

-200 to 1300

-320 to 2370



*1: (1) No.21 to 39: IEC584, JIS C 1602-1995

(2) No.40 to 50: ASTM
(3) No.51 to 56: DIN43710

Measuring range

No.

Input type

°C

°F

40

W-WRe26 0 to

2315 32

to 4200

41

WRe5-WRe26

0 to 2315

32 to 4200

43

PtRh40-

PtRh20

0 to 1888

32 to 3400

44

-50.0 to 290.0

32.0 to 550.0

45

-50.0 to 600.0

32 to 1110

46

NiMo-Ni

50 to 1310

32 to 2350

47

CR-AuFe 0.0 to

280.0K

0.0 to 300.0K

48

0.0 to 350.0

-140.0 to 660.0

49

0.0 to 650.0

-140 to 1200

50

Platinel

0 to 1390

-140 to 2530

51

-200.0 to 250.0

-320.0 to 480.0

52

-200.0 to 500.0

-320.0 to 930.0

53

U

-200.0 to 600.0

-320 to 1110

54

-200.0 to 250.0

-320.0 to 480.0

55

-200.0 to 500.0

-320.0 to 930.0

56

L

-200 to 900

-320 to 1650


3) Resistance thermometer input (*2)

Measuring range

No.

Input

type

°C

°F

70

-140.0 to 150.0 -220.0

to 300.0

71

-200.0 to 300.0 -320.0

to 550.0

72

Pt100

(JIS’97)

-200.0 to 850.0 -320

to 1560

73

-140.0 to 150.0 -220.0

to 300.0

74

-200.0 to 300.0 -320.0

to 550.0

75

Pt100

QPt100

JIS’89

-200.0 to 649.0 -320

to 1200

76

-140.0 to 150.0 -220.0

to 300.0

77

-200.0 to 300.0 -320.0

to 550.0

78

JPt100

-200.0 to 649.0 -320

to 1200

79

Pt50 -200.0 to 649.0 -320

to 1200

80

Pt-Co 4.0 to 374.0K 4.0

to 374.0K


*2: (1) No.70 to 72: IEC751(1995), JIS C 1604-1997

(2) No.73 to 75: IEC751(1983), JIS C 1604-1989

JIS C 1606-1989

(3) No.76 to 78: JIS C 1604-1981

JIS C 1606-1989

(4) No.79: JIS C 1604-1981


Decimal point position: Even if the decimal point position is programmed in the printing range, the actual

display/printing position is shown as described in the table above depending on the
range No. For changing the decimal point position, see Section 11.2 “Scale
programming”.

Engineering units: Engineering unit is shown as described in the table above depending on range No.

(Temperature unit is fixed to “

°C” except No. 47 and 80). For changing the engineering

unit, see Section 11.8 “Unit programming”.


Decimal point position and engineering units

Remarks