2.8.2 Using an Internal Oscillator Circuit Board
Kinds of Oscillator Circuit Boards

An oscillator module (20MHz) is mounted on the IC17 at factory setting. If you change the frequency, replace the oscillator

module.

(1) Replacing the Oscillator module

Remove the MCU unit from the E100 emulator main unit, and replace the oscillator module of the IC17 (see Figure 2.7).

CN

1

40a

1a

CN

2

40a

1a

CN

3

40a

1a

40b

1b

CN

4

40a

1a

40b

1b

40b

1b

CN6

1

50

51

100

CN5

1

50

51

100

40b

1b

40b

1b

40b

1b

1

4

7

8

11

14

IC17

1

4

7

8

11

14

SG-8002DC

SG-8002DB

EPSON TOYOCOM

SG-8002DC/DB Series

(power voltage 2.7--3.6V : PC/SC)

Figure 2.7 Replacing the oscillator module

CAUTION

Note on Replacing the Oscillator Module and Oscillator Circuit Board:

z

Always shut OFF power when replacing the oscillator module. Otherwise, internal circuits may be damaged.