R0E530640MCU00 User’s Manual
2. Setup
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 25 of 229
2.3 Connecting/Disconnecting the MCU Unit to/from the E100 Emulator Main Unit
Figure 2.3 shows the procedure for connecting the MCU Unit to the E100 Emulator Main Unit.
Connecting
100
HIGH PE
RFORMAN
CE
EMULAT
OR SYST
EM
R0
E5
306
50M
CU
00
E100 emulator main unit
R0E001000EMU00
MCU Unit
R0E530640MCU00
Insert the MCU unit
following the inside
rails of the main unit.
100
HIGH PER
FORMAN
CE
EMULAT
OR SYST
EM
R0
E5
306
50M
CU
00
Push the MCU unit down
to check it is attached properly.
Disconnecting
R0
E5
306
50M
CU
00
100
HIGH PER
FORMAN
CE
EMULATO
R SYST
EM
Pull the MCU unit up.
Figure 2.3 Connecting/Disconnecting the MCU Unit to/from the E100 Emulator Main Unit
CAUTION
Note on Connecting the MCU Unit to the E100 Emulator Main Unit:
z
Always shut OFF power when connecting the MCU unit to the E100 emulator main unit. Otherwise, internal
circuits may be damaged.