5.9.6 Setting Capture/Do not Capture Conditions
If the selected trace mode is Fill until stop, Fill until full or Fill around TP, you can specify Capture/Do not Capture conditions.
You can choose to extract only the necessary portions of trace information specified by events or delete the unnecessary
portions.

(1) Capture/Do not Capture conditions

There are following types of conditions.

Table 5.22 Capture/Do not Capture conditions

Type Description

Between two events

Cycles extracted begin when a start event occurs and end
with the next to last end event occurs (the cycle where an
end event occurs is not extracted).

Duration of an event

Only cycles where a specified event occurred are extracted.

Duration of an event
occurring in a subroutine

Only cycles where a specified event occurred in a specified
address range (subroutine or function) are extracted.

Extraction

Instruction accessing
specific data

Instructions that accessed specified data are detected.

Between two events

Cycles extracted begin when a start event occurs and end
with the next to last end event occurs (the cycle where an
end event occurs is not extracted).

Duration of an event

Only cycles where a specified event occurred are deleted.

Deletion

Duration of an event
occurring in a subroutine

Only cycles where a specified event occurred in a specified
address range (subroutine or function) are deleted.


Select the conditions you want to set from the list box that is displayed when you select Extract or Delete in the Record
condition group box of the Trace conditions dialog box.

Figure 5.54 Record condition group box


Then click the Detail button. A page in which you can set events will be displayed.