beautypg.com

NEC Server 140Rc-4 User Manual

Page 335

background image

Upgrading Your Server 9-49

9.

Gently push the levers to the upright position until they engage the notches in the
DIMM.(3)

10.

Install the components you removed in steps 1 to 5.

11.

Power on the server and verify that POST displays no error messages.

If POST displays an error message, take a note on the message and see the POST error
messages listed in Chapter 8.

12.

Start the SETUP and select [Advanced] → [Memory Configuration] to verify that the

installed DIMM shows the status "Normal". (See Chapter 4 or details.)

13.

Select "Yes" for [Reset Configuration Data] on the [Advanced] menu.

This setting is required to change the hardware configuration data. See Chapter 4 for
details.

14.

If Windows Server 2003 or Windows 2000 is in use, set the paging file size to the
recommended value (total memory size * 1.5) or a greater value. See Chapter 5 for details.

This manual is related to the following products: