NEC Server 140Rc-4 User Manual
Page 156

4-46 Configuring Your Server
The following figure illustrates the jumper switch location.
Pins for protecting/clearing the passwords
Short-circuit these two pins to clear the passwords.
Open these two pins to protect the passwords (factory-set).
Pins for protecting/clearing the CMOS data
Short-circuit these two pins to clear the CMOS data.
Open these two pins to protect the CMOS data (factory-set).
7.
Reassemble the server and press the POWER switch.
8.
Run BIOS setup utility to reconfigure the baseboard.
9.
Save and exit the utility.
10.
Restore the jumper switch setting and power on the server for reconfiguration.
NOTE:
Place the clip over the jumper pins 1 and 2 after use to keep
the pin.
Pins 1 and 2.
Pins for protecting/clearing
the passwords.
Use the clip over
pins 1 and 2.
Pins for protecting/clearing
the CMOS data.
JP4
JP5
JP6