Troubleshooting 8-17

Error
code

Error message

Recommended Action

0B50

Processor #1 with error taken off line.

0B51

Processor #2 with error taken offline.

0B52

Processor #3 with error taken offline.

0B53

Processor #4 with error taken offline.

The CPU is degraded. Contact your
service representative.

0B5F

Forced to use Processor with error

Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.

0B60

DIMM group #1 has been disabled

0B61

DIMM group #2 has been disabled

0B62

DIMM group #3 has been disabled

Contact your service representative.

0B70

The error occurred during temperature sensor
reading.

Contact your service representative.

0B71

System Temperature out of the range.

A fan failure or fan clogging may occur.
Contact your service representative to
request the maintenance.

0B74

The error occurred during voltage sensor
reading.

0B75

System voltage out of the range.

0B78

The error occurred during fan sensor reading

Contact your service representative.

0B7C

The error occurred during redundant power
module confirmation

Contact you service representative to
replace the power supply unit.

0B7D

The normal operation can't be guaranteed with
use of only one PSU

Contact you service representative to add an
additional power supply unit or replace the
existing power supply unit.

0B80

BMC Memory Test Failed.

0B81

BMC Firmware Code Area CRC check failed.

0B82

BMC core hardware failure.

0B83

BMC IBF or OBF check failed.

0B8A

BMC SEL area full.

0B8B

BMC progress check timeout.

0B8C

BMC command access failed.

0B8D

Could not redirect the console - BMC Busy -

0B8E

Could not redirect the console - BMC Error -

0B8F

Could not redirect the console - BMC
Parameter Error -

0B90

BMC Platform Information Area corrupted.

0B91

BMC update firmware corrupted.

Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service
representative.

0B92

Internal Use Area of BMC FRU corrupted.

All the commands and functions other than
the FRU command and the EMP function
can be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.

0B93

BMC SDR Repository empty.

Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.