9-48 Upgrading Your Server

Installation

Install a DIMM in the following procedure.

IMPORTANT:

Install four additional DIMMs for each group because

the server uses interleaved memory. If DIMMs of different
specifications* are installed in a group, the server does not operate
normally.

* DIMM specification is shown on the label attached to the DIMM as

follows:

Example: Frequency of 200 MHz, buffered, capacity of 128 MB,

raw address of 12 bits, column address of 10 bits, and
single side

200 / B / 128 / R12 C10 S

Single side

Column address

Raw address

Capacity

Buffered

Frequency

1.

See the section "Preparing for Installation and Removal" described earlier to prepare.

2.

Pull out the server from the rack.

3.

Remove the rear access cover.

4.

Remove the CPU access cover.

5.

Remove the memory board.

6.

Locate the DIMM group which you are going to install DIMMs.

7.

Open the levers at both ends of the socket (1).

IMPORTANT:

To avoid damaging the lever, do not apply an excess

force to the lever.

8.

Push the DIMM straight into the socket (2).

IMPORTANT:

Use extreme care when installing a DIMM. Applying

too much pressure can damage the socket. Keyed DIMMs insert only
one way.