Planning and engineering
Traffic (CCS)
Traffic (Erlang)
Number of ports
2000
55.56
74
2500
69.44
90
3000
83.33
106
3500
97.22
121
4000
111.11
137
4500
125
152
5000
138.89
168
6000
166.67
198
7000
194.44
228
8000
222.22
258
9000
250
288
10 000
277.78
318
20 000
555.56
611
30 000
833.33
908
40 000
1111.11
1205
50 000
1388.89
1502
60 000
1666.67
1799
70 000
1944.44
2096
Basic Client Configuration
The PCAG and PCAM Class of Service (CLS) have been introduced. Basic
Client Configuration (BCC) can program the new Class of Service (CLS)
parameters PCAG or PCAM for PCA TNs. The CLS parameter PCAG will
be the default for all PCA TNs and PCAM will be the required value for all
PCAs associated with OCS 2007.
LD 11 supports the administration of telephones. BCC uses REQ
commands, such as NEW, CHG, and OUT. In LD 20, BCC uses the PRT
command to retrieve phones from the Call Server.
Port use
The CS 1000 uses the following ports related to TCP and TLS.
•
5060: TCP
•
5061: TLS
The dynamic port range used by Office Communicator for SIP/RTP is 1024
- 65535.