Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual
Page 92
Operating Instructions
COMPAX-M / -S
Individual configuration of synchronous motors
92
The following parameters can be read directly from the motor type plate :
♦
P101
number of motor terminals
♦
P102: EMC [V/1000 rpm]
These two values are included in the motor type description (type).
HDY xxx Ax-xxxS
S: sinusoidal EMF
T: trapezoidal EMF
EMF given in V per 1000 rpm
number of poles of motor
motor type: HDY,HJ or HBMR
motor length
flange size of motor
♦
P103: motor moment of inertia (inertia)
[kgmm
2
]
♦
P109: stator inductivity (ind) [µH]
♦
P113: maximum mechanical speed (max) [rpm]
♦
P116: stator resistance (res) [
Ω
]
♦
P105: effective value of nominal current IN [mA]
HBMR motors:
I
N
= 0.95 * I
0
HDY motors:
I
N
= 0.85 * I
0
HBMR 55 and 70:
I
N
= 0.85 * I
0
♦
P106: nominal torque MZ
HBMR motors:
M
N
= 0.92 * M
0
HDY motors:
M
N
= 0.82 * M
0
HBMR 55 and 70:
M
N
= 0.82 * M
0
when I
0
= idle current
M
0
= idle torque
The other parameters are derived from the type plate data
Nominal motor speed for the HBMR motors
♦
P104: nominal motor speed [rpm]
EMC
n
N
[min
-1
]
U
ZW
=300V
U
ZW
=560V
32
5000
44
4000
5000
64
2600
5000
88
3500
130
2400
180
1700
260
1250
360
800
Motor type plate
Proceed as follows:
with
EMC: counter EMC
n
N
: nominal speed
U
ZW
: intermediate circuit voltage
300V: with 230V AC
560V: with 3 * 400V AC