beautypg.com

Configuration, Motor type, Ramps – Parker Products COMPAX-M /-S (L) User Manual

Page 75

background image

Configuration

Configuration parameters

75

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

the max. travel distance is limited to

±

4 million units. This corresponds to 61

revolutions at a maximum resolution of 65 536 increments per motor revolution.
The maximum travel distance can be increased by reducing P83. Meaning:

P83

Maximum travel in motor revolutions

16

±

250 000

32

±

125 000

64

±

62 500

128

±

31 250

256

±

15 625

512

±

7812

1024

±

3906

2048

±

1953

4096

±

976

8192

±

488

16 384

±

244

32 768

±

122

65 536

±

61

In continuous mode, this limitation applies to a single command.
In normal mode, this limit applies to the entire displacement area.

Parameter P100
The motor parameters are required for COMPAX motor-specific settings.
The motor parameters of the HAUSER motors recommended for COMPAX are
available in a list in ServoManager / ParameterEditor and can be selected from
there.
You can configure additional motors using the "External motor" function.

Sine-commuted motors (sinusoidal EMC)

Resolver / SinCos (see start-up manual under "Technical data" on Page 64).

The nominal currents of the motors and units must be adapted.
If you are using nominal currents which are smaller in relation to the unit
nominal current, current recording will be less accurate.

Parameter P94

P94 ="1"
Simplest, time-oriented function; not smooth

t

V

t

a , M

0

0

ta

1,0

Current requirement: 1 times

Motor type

Basic conditions
for external
motors:

Ramps

linear