Operating instructions, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 170

background image

Operating Instructions

COMPAX-M / -S

Process coupling using HEDA (Option A1 / A4)

170

Master output
quantites:
P184=

Slave
input
quanti-
ties:
P188=

Can be used in
slave unit
versions:

Settings in master and slave for
adapting the process quantities:

P98 is identical in all units

40

40

CPX 60, CPX 70

P143

s

=P143

40

M

(CPX 00 CPX 60, CPX 70)

43

CPX 70

42

(CPX 70)

42

CPX 70

P143

s

=P143

M

43

140*

CPX 60, CPX 70

P143

s

=P143

M

(CPX 70)

43

CPX 70

44

140*

CPX 60, CPX 70

P143

s

= 2

14

= 16384

(CPX 00 CPX 60, CPX 70)

43

CPX 70

45

140*

CPX 60, CPX 70

P143

s

= 2

14

= 16384

(CPX 00 CPX 60, CPX 70)

43

CPX 70

46

(CPX 00 CPX 60, CPX 70)

42

CPX 70

P143

s

=P143

M

When the encoder position P184=40 is transferred, the encoder position is
transferred into high word and the duration period of the pulses is transferred into
low word to support a duration period measurement in the slave.
If a mixture of application purposes is undertaken, e.g. master P184=44 (nominal
value) and slave with encoder coupling, then the slave must be informed using
P188=140 (in such cases only the high word is processed).

1st unit: Master

Slave

COMPAX XX60
COMPAX XX70

(P31=1)

Encoder input
P184=40 (encoder
position+duration
period)
P188=40

COMPAX XX60
COMPAX XX70

(P31=9)

P188=40
(encoder input;
duration period
available)

Coupling of several axes to one
encoder; HEDA distributes the signals

O1/O3

Slave 2

Slave 1

Master

BUS2/01

SSK14

SSK15

GBK11

I2

O1/O3

O1/O3

P98 and P143 must have the same
values for master and slave!

Replacing the encoder emulation using
HEDA bus

O1/O3

Slave 2

Slave 1

Master

BUS2/01

SSK14

SSK15

O1/O3

O1/O3

Note:

There is a time misalignment

between master and slave of 2ms;
Remedy:

activate identical program

sets together using "Fast start".

COMPAX XX00
COMPAX XX60
COMPAX XX70

P184=44 (nominal
position value) or
P184=45 (actual
position value)
P188=0

COMPAX XX60
COMPAX XX70
P188=140
Setting P143 =
16384

(¼ of the increments
are always in P143
as quadrupling
occurs during
encoder inputs)

40

P143

s

: parameter P143 of the slave

P143

M

: parameter P143 of the master

Permissible
combinations and
required
parameter
settings:

Application

examples: