beautypg.com

Compax 25xxs-specific technical data, Start-up manual, Compax-m / -s – Parker Products COMPAX-M /-S (L) User Manual

Page 32: 2 compax 25xxs-specific technical data, Fuse protection: 16a, Compax 25xxs: ≤ 1.0 kw unlimited with r

background image

Start-up manual

COMPAX-M / -S

32

!

Control voltage 24V DC

±

10% ripple <1V

SS

Fuse protection: 16A

X4

PE

L3

L2

L1

PE

N

L

3 x

23

0V

AC

1 x

23

0V

AC

+

-

-

+

PE

W

V

U

PE

B

B

-

+

brake

resistance

1

234

PE
L3
L2
L1

12

3

4

PE

L

N

12

-
+

Connections for
3 x 230V AC

Connections for
1 x 230V AC

Bus system
X5 IN

X2

X3

X1

F19 3.16 AT

AC

supply

24V DC

supply

Bus system

X7 OUT

motor and

motor brake

24V control voltage

230

V A

C

23

0V

AC

230V

A

C

L1

L2

L3

m

a

x

.

230

V

A

C

+

1

0%

lin

e

to

lin

e vo

ltag

e

!

Note! Do not apply 3 * 400V AC.

Only wire up brake in motors with a holding brake! Otherwise, do not
wire up.

7.5.2 COMPAX 25XXS-specific technical data

!

Energy recuperated during braking is stored in the supply capacitors. The
capacity and storable energy is:
COMPAX 25XXS:

1000

µ

µ

µ

µ

F / 27 Ws

If the recuperated energy causes overvoltage, then external ballast resistances can
be engaged.

Braking power

Duration

Cooling

down time

COMPAX 25XXS:

1.0 kW

unlimited

with R

ext

56

:

2.5 kW

<2s

10s

We can supply external ballast resistances for COMPAX 25XXS
(see Page 193).

Connecting ballast resistance to COMPAX-S
The ballast resistance is connected to B+, B- and, if necessary, PE.
Output X4 is protected from short circuits.

Mating connectors for X1,..X4 from Phoenix are included with the following type
designations:
X1: MSTB2.5/8/STF-5.08 (with screw connection)
X2: MSTB2.5/4/ST-5.08 (without screw connection)
X3: MSTB2.5/2/ST-5.08 (without screw connection)
X4: MSTB2.5/3/STF-5.08 (with screw connection)
You can acquire Phoenix housings for these connectors and these can be used
once adapted to our cables. Designation: KGG-MSTB2.5/(pin number).

Overvoltage
limitation

Maximum braking
power with
external ballast
resistance

Mating
connectors X1,
X2, X3 and X4