Accessories and options, Compax-m / -s, Individual connections – Parker Products COMPAX-M /-S (L) User Manual
Page 180: Applications with encoder, Encoder module and accessories
Accessories and options
COMPAX-M / -S
180
E2
Encoder input module with line terminator for
individual connections; not for creating an
encoder bus.
E3
E3: Encoder emulation
E4
Encoder input module without line terminator
for creating an encoder bus.
Not for COMPAX 1000SL:
With COMPAX 1000SL, the
signal interface usually
present can be configured
either as an encoder input or
encoder simulation (see Page
61.
EAM4/01
Encoder distributor for creating an encoder bus.
Design:
70mm
80
mm
BUS1/01
Bus termination for encoder distributor EAM4/01.
BUS6/01
Bus termination for encoder - COMPAX 1000SL connection
GBK11/..
Encoder cablefor connecting COMPAX with an encoder.
SSK7/..
Connector cable between encoder distributors or from an encoder emulation.
SSK4/..
Connector cable between COMPAX and encoder distributor.
SSK17/..
Connector cable between COMPAX 1000SL (encoder emulation) – COMPAX
Channel 1
Channel 2
Pin
X1: IN
X2: OUT
X3: IN
X4: OUT
1
Screen
Screen
Screen
Screen
2
NC
N1
NC
N2
3
NC
B1
NC
B2
4
NC
1A
NC
A2
5
N1
NC
N2
NC
6
B1
NC
B2
NC
7
1A
NC
A2
NC
8
+5V
NC
+5V
NC
9
NC
N1/
NC
N2/
10
NC
B1/
NC
B2/
11
NC
O1/
NC
A2/
12
N1/
NC
N2/
NC
13
B1/
NC
B2/
NC
14
O1/
NC
A2/
NC
15
GND
NC
GND
NC
Applications with encoder:
Encoder COMPAX
♦
Cable: GBK 11/..
♦
Encoder input module E2 with line terminator, or for
♦
COMPAX 1000SL: Configured as encoder input (P144=4; P146=0) and with bus
termination BUS 6/01 (sits as an intermediate connector on X13)
SV drive COMPAX
♦
Cable: SSK 7/..
Note! Note direction.
cable in: SV drive
cable out: COMPAX
♦
Encoder input module E2 with line terminator, or for
♦
COMPAX 1000SL: Configured as encoder input (P144=4; P146=0) and with bus
termination BUS 6/01 (sits as an intermediate connector on X13).
Encoder module
and accessories:
Assignment of
EAM4/01
(corresp. X13)
Individual
connections
Depth: 40 mm without mating connector
The module is engaged on the terminal
bus bar.