beautypg.com

Accessories and options, Compax-m / -s, Individual connections – Parker Products COMPAX-M /-S (L) User Manual

Page 180: Applications with encoder, Encoder module and accessories

background image

Accessories and options

COMPAX-M / -S

180

E2

Encoder input module with line terminator for
individual connections; not for creating an
encoder bus.

E3

E3: Encoder emulation

E4

Encoder input module without line terminator
for creating an encoder bus.

Not for COMPAX 1000SL:
With COMPAX 1000SL, the
signal interface usually
present can be configured
either as an encoder input or
encoder simulation (see Page
61.

EAM4/01

Encoder distributor for creating an encoder bus.

Design:

70mm

80

mm

BUS1/01

Bus termination for encoder distributor EAM4/01.

BUS6/01

Bus termination for encoder - COMPAX 1000SL connection

GBK11/..

Encoder cablefor connecting COMPAX with an encoder.

SSK7/..

Connector cable between encoder distributors or from an encoder emulation.

SSK4/..

Connector cable between COMPAX and encoder distributor.

SSK17/..

Connector cable between COMPAX 1000SL (encoder emulation) – COMPAX

Channel 1

Channel 2

Pin

X1: IN

X2: OUT

X3: IN

X4: OUT

1

Screen

Screen

Screen

Screen

2

NC

N1

NC

N2

3

NC

B1

NC

B2

4

NC

1A

NC

A2

5

N1

NC

N2

NC

6

B1

NC

B2

NC

7

1A

NC

A2

NC

8

+5V

NC

+5V

NC

9

NC

N1/

NC

N2/

10

NC

B1/

NC

B2/

11

NC

O1/

NC

A2/

12

N1/

NC

N2/

NC

13

B1/

NC

B2/

NC

14

O1/

NC

A2/

NC

15

GND

NC

GND

NC

Applications with encoder:

Encoder COMPAX

Cable: GBK 11/..

Encoder input module E2 with line terminator, or for

COMPAX 1000SL: Configured as encoder input (P144=4; P146=0) and with bus

termination BUS 6/01 (sits as an intermediate connector on X13)

SV drive COMPAX

Cable: SSK 7/..
Note! Note direction.
cable in: SV drive
cable out: COMPAX

Encoder input module E2 with line terminator, or for

COMPAX 1000SL: Configured as encoder input (P144=4; P146=0) and with bus

termination BUS 6/01 (sits as an intermediate connector on X13).

Encoder module
and accessories:

Assignment of

EAM4/01

(corresp. X13)

Individual
connections

Depth: 40 mm without mating connector
The module is engaged on the terminal
bus bar.