Rs232 interface, Absolute value sensor (option a1), Interfaces – Parker Products COMPAX-M /-S (L) User Manual
Page 59: 8 rs232 interface, 9 absolute value sensor (option a1), Wiring diagram ssk1/...:compax - pc/terminal, Cable plan gbk1/..: compax absolute value sensor, Apply screen on both sides to surface
Interfaces
59
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
7.9.8 RS232
interface
Wiring diagram SSK1/...:COMPAX - PC/terminal
PC / terminal
9-way Sub-D-pin
plug shell with screwed
connection UNC4-40
9pol. Sub-D-socket board
housing
GND
housing
GND
7 x 0.25mm + shield
2
2
3
4
6
5
7
8
RxD
TxD
DTR
DSR
RTS
CTS
2
3
4
6
5
7
8
RxD
TxD
DTR
DSR
RTS
CTS
9
+5V
1
n.c.
1
5
6
9
1
5
6
9
X6
Apply screen on both sides to surface.
7.9.9 Absolute value sensor (option A1)
The option A1 cannot be used for COMPAX 1000SL.
X16
11
3
10
2
1
8
1
2
3
4
5
6
7
8
9
10
11
12
1
5
6
9
T+
T-
D+
D-
+24V
GND
6
1
8
3
9
5
2
4
7
n.c.
n.c.
n.c.
absolute enoder
plug :
9-way Sub-D-pin
plug housing with
screwed connection
UNC4-40
plug :
C12FUR
4 x ( 2 x 0.25mm ) + shield
2
housing
housing
Cable plan
GBK1/..: COMPAX
absolute value
sensor