Installation and dimensions of compax 35xxm, Compax 35xxs unit features, 2 installation and dimensions of compax 35xxm – Parker Products COMPAX-M /-S (L) User Manual
Page 27: Mains supply fuse protection, Regeneration mode, Specific technical data, Installation and dimensions of compax 35xxm 27, Fuse protection: max. 16a
COMPAX 35XXS unit features
Installation and dimensions of COMPAX 35XXM
27
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
L1
L2
L3
PE
PE
PE
+
-
U
V
W
PE
+
-
F1
Mains Input
DC - In
Braking
Motor
Motor
X 20
24 V
X 21
Resistance
X 22
X 1
Brake
X 23
motor
AC - voltage
up to 500V AC
24V control
voltage
external
ballast
resistor
motor
brake
F1
3.16A
Supply voltage up to max. 3 * 500V AC
Operating range: 3*80V AC - 3*500V AC; 45 - 65 Hz.
Typical AC mains: 400V
±
10%; 460V
±
10%;480V
±
5%
!
Layout of contactors for the power supply:
Capacity according to device performance: Application group AC3
Switching on the operating voltage for a second time:
Before switching on the operating voltage for a second time, you must wait for at
least 2.5 minutes otherwise you may overload the condenser load resistance.
Control voltage
!
21.6V to 26.4V DC
•
Ripple: < 1V
SS
•
fuse protection: max. 16A
Mains supply fuse protection
62A K circuit breaker or suitable Neozed conventional fuse.
Regeneration mode
!
Storable energy: 3450µF/542 Ws
!
External ballast resistance: 10
Ω
/2 kW
For the external ballast resistors available, please see Page 193.
7.4.2 Installation and dimensions of COMPAX 35XXM
390
340
86
65
65
218
190
45
0
36
3
190
43
0
10 14
38
Digital
COMPAX-M
X5
X7
IN
OUT
X19
Control
H1
X6
In pu t
O utp ut
S ta tus
Value
+
-
E n ter
Re ady
E r ro r
R S 23 2
Test
C o n tr ol
X8
X1 0
X9
X1 1
N u m b er
Fastening with 4 M6 hex-socket head screws.
Plan view
Specific technical
data
Note!