beautypg.com

Nmd connector assignment, Technical data / power features nmd, Mains module nmd10/nmd20 – Parker Products COMPAX-M /-S (L) User Manual

Page 23: 3 nmd connector assignment, 4 technical data / power features nmd, Ce conformity, Nmd connector assignment 23, Ripple: < 1v, Fuse protection: max. 16a dissipation power, Without fan: max. 120w (standard)

background image

Mains module NMD10/NMD20

NMD connector assignment

23

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

7.3.3 NMD connector assignment

X1/1

L1

X1/2

L2

X1/3

L3

X1/4

PE

X1/5

+24V

X1/6

0V

X1:
voltage
supply

+24V
0V

X3:
Control
voltage

X8/2

GND

X8/1

+24V

X8/3

P

X8/4

S

X8/5

+24V

X8/6

15V-24 V emerg. stop

X8

X8/6

housing

stand by

+LS
-LS

X2:
power inter-
mediate loop

PF

X1/1

L1

X1/2

L2

X1/3

L3

X1/4

PE

X1/5

+24V

X1/6

0V

+LS
-LS

PE

X6: input bus systems

X7: output bus systems

Assignment depends on the
bus system

Assignment depends on the
bus system

7.3.4 Technical data / power features NMD

Function
Generates DC current when run directly off a mains source.

CE conformity

!

EMC immunity/emissions as per EN61800-3.

!

Safety: VDE 0160/EN 50178.

Output power

Nominal power

Peak power

NMD10:

10 kW

20 kW (<3s)

NMD20:

20 kW

40 kW (<3s)

Mains fuse protection
NMD10: 16A (K circuit breaker in 20A)
NMD20: 35A
K circuit breaker or similar Neozed fusible cut-out.

Supply voltage up to max. 3*500V AC

!

Operating range: 3*80V AC - 3*500V AC, 45 - 65 Hz.

Typical AC mains: 400V

±

10%; 460V

±

10%; 480V

±

5%

!

Layout of contactors for the power supply:

Capacity according to device performance: Application group AC3.

Control voltage

!

21.6V up to 26.4V DC (0.8A)

!

Ripple: < 1V

SS

!

Fuse protection: max. 16A

Dissipation power

!

without fan: max. 120W (standard)

!

with fan: max. 250W.