beautypg.com

Arithmetic, Parameter assignments, 30 arithmetic – Parker Products COMPAX-M /-S (L) User Manual

Page 113: 1 parameter assignments, Positioning and control functions

background image

Positioning and control functions

Arithmetic

113

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

8.4.30 Arithmetic

8.4.30.1 Parameter assignments

N001: P40 = 123.456

N002: V19 = P1
The assignments for parameters and variables are defined with an equal sign. The
variables are represented by V0 to V39.

The assignment of variables is also possible as a direct command, e.g. from a
terminal.

a parameter Pxxx or

a variable Vxxx (V0 - V39) or

a curve point Ixxxx (digital or analogue auxiliary functions when using COMPAX

XX70) or

a curve point Fxxxx (set points when using COMPAX XX70)

an operand

or

a simple arithmetic term

22

a parameter Pxxx or

a variable Vxxx (V1 - V39) or

a status value Sxxx or

a constant with max. 8 significant digits + sign + decimal point.

All parameters may be assigned.
The commands "VP" and "VC" (with which the parameters are validated) can be
programmed in the program.

N123: P081=30

(modifies moment of inertia)

N124: VC

N234: P013=10

(modifies lag tolerance)

N235: VP

COMPAX XX70: the curve memory is also accessible:

N200: F5450=0.5 (modifies idle postion of 1st curve)
N201: I5460=128 (modifies master cycle route of 1st curve)
N202: VF

(validates curve)

For more information, see operating instructions for electronical curve
control

.

22

Curve points can only be modified using an assignment; an arithmetic term is

not allowed.

Syntax:

Note

Items permitted to

the left of the equal

sign:

Items permitted to

the right of the

equal sign:

An operand is:

Example:

Curve memory

Example: