beautypg.com

Appendix, Compax-m/s – Parker Products COMPAX-M /-S (L) User Manual

Page 216

background image

Appendix

COMPAX-M/S

COMPAX standard parameters

216

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

Max. total moment of inertia

P82

With linear motors:

(

)

2

max

2

1000

126

P

m

82

P

Π

=

kgmm2

0

0.00

200 000

VC

Travel per motor revolution

P83

With linear motors: P83 = P126

µ

m or

increm.

10

0.00

4 000 000

µ

m

65 536

Inkr.

VC

P90

Unit for travel

"0": increments
"1": mm
"2": inch

VC

P93

Operating mode

"1": normal mode
"2": Continuous mode
"4": speed control mode

54

55

P94

Ramp shape

"1": linear

"2": smooth "3": quadratic.

56

P96

Transmission factor for the reset route of S2
option. ="0": no reset function.

-

0

0

4095

VC

P98

Travel of axis per encoder revolution

corresp.
P90

0

0.0000000

4 000 000

VC

No.

Valid

for57

P100 Motor number

Motor selection

VC

Number of terminals

A,S

P101

Linear motor: P101=2

L

2

2

12

VC

EMC

S

P102

P102=EMC[V/(m/s)] * P126/60 000

L

V * min/

1000

10

400

VC

Moment of inertia

A,S

P103

Linear motor:

(

)

2

2

1000

126

103

Π

=

P

m

P

Forcer

L

kgmm

2

0

200 000

VC

Nominal speed

A,S

P104

Linear motor:

126

60000

1000

104

P

V

P

al

min

no

=

L

min

-1

500

9000

VC

P105 Nominal current

A,S,L mA

200

100 000

VC

Nominal torque

A,S

P106

Linear motor:

(

)

Π

=

2

1000

126

106

P

F

P

al

min

no

L

mNm

0

100 000

VC

P107 Pulse current

A,S,L %

100

400

VC

P108 Max. time in current limit (P16)

A,S,L ms

1000

5000

VC

P109 Stator inductivity

A,S,L

µ

H

0

200 000

VC

P110 Magnetization current

A

mA

100

0.7 * P105

VC

P111 Rotor time constants

A

ms

5

2000

VC

54

When in speed control mode, P25 must > 0.

55

From next process command

56

From next process command

57

A: parameter for asynchronous motors

S: parameter for synchronous motors
L: parameter for linear motors