Compax-m unit features, L1 l2 l3 pe, U v w pe – Parker Products COMPAX-M /-S (L) User Manual
Page 19: Brake, Power supply, Control voltage, Wiring up the motor, Wiring up mains power / control voltage
COMPAX-M unit features
COMPAX-M system network, NMD10 / NMD20 mains module
19
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
Unit side
H A U S E R
P O W E R S U P P L Y
X 6
X 7
X 8
R ea dy
E rro r
R S
4 85
IN
O U
T
C on tr ol
H A U S E R
C O
M P A X - M
D IG IT
A L
S ta tus
N um b er
X 6
X 8
X 10
-
+
E nte r
R ea dy
E rro r
R S
2 32
In pu t
O ut pu t
T es t
C on tr ol
X 9
X 11
V alu e
D IG IT
A L
S ta tus
N um b er
X 6
X 8
X 10
-
+
E nte r
R ea dy
E rro r
R S
2 32
In pu t
O ut pu t
T es t
C on tr ol
X 9
X 11
V alu e
CO M PA X- M
M oti on &
C
o ntr ol
CO M PA X- M
M oti on &
C
o ntr ol
D IG IT
A L
S ta tus
N um b er
X 6
X 8
X 10
-
+
E nte r
R ea dy
E rro r
R S
2 32
In pu t
O ut pu t
T es t
C on tr ol
X 9
X 11
V alu e
cable conduit
L1 L2L3 PE 24V
+ -
24V
+
-
PE
+LS
-LS
U V W PE brake
PE+ -
X1
X2
X3
X5
X1
X2
X3
X4
X4
U V W PE
PE
+ -
X1
1
2
3
4
5
bl
ac
k 1
bl
ac
k 2
bl
ac
k 3
gr
een/
ye
ll
ow
fr
ee
bl
ac
k 4
bl
ac
k 5
brake
Note the screened connection of the motor cable on the
upper unit side.
Clamp the motor cable with the open place of the screen
braid under the ground terminal (see figure on the right).
Only wire up brake in motors which have a holding brake! If not, do not
wire.
The mains supply and the control voltage supply are provided by the mains
module.
Power supply:
!
3*80V AC – max. 3*500V AC; 45 - 65Hz
!
Fuse protection:
NMD10: 16A (K circuit breaker in 20A)
NMD20: 35A
K circuit breaker or similar Neozed
fusible cut-out.
Control voltage
!
24V DC
±
10%
Ripple <1V
SS
Fuse protection: max. 16A
COMPAX-M
Motion & Control
COMPAX-M
Motion & Control
HAUSER
POWER SUPPLY
X6
X7
X8
Ready
E rr or
RS485
IN
OUT
C on tro l
HAUSER
CO MPAX -M
DIGITAL
S ta tu s
Nu m ber
X6
X8
X10
-
+
E nter
Ready
E rr or
RS232
Inp u t
O utp u t
Test
C on tro l
X9
X11
Value
DIGITAL
S ta tu s
Nu m ber
X6
X8
X10
-
+
E nter
Ready
E rr or
RS232
Inp u t
O utp u t
Test
C on tro l
X9
X11
Value
DIGITAL
S ta tu s
Nu m ber
X6
X8
X10
-
+
E nter
Ready
E rr or
RS232
Inp u t
O utp u t
Test
C on tro l
X9
X11
Value
cable conduit
L1 L2L3 PE 24V
+ -
24V
+
-
PE
+LS
-LS
U V W PE brake
PE + -
X1
X2
X3
X5
X1
X2
X3
X4
X4
power supply
module
L1 L2 L3 PE
+ -
X1
1
2
3
4
5
24V
Wiring up the
motor
Screened
connection
Wiring up mains
power / control