beautypg.com

Compax-m unit features, L1 l2 l3 pe, U v w pe – Parker Products COMPAX-M /-S (L) User Manual

Page 19: Brake, Power supply, Control voltage, Wiring up the motor, Wiring up mains power / control voltage

background image

COMPAX-M unit features

COMPAX-M system network, NMD10 / NMD20 mains module

19

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

Unit side

H A U S E R

P O W E R S U P P L Y

X 6

X 7

X 8

R ea dy

E rro r

R S

4 85

IN

O U

T

C on tr ol

H A U S E R

C O

M P A X - M

D IG IT

A L

S ta tus

N um b er

X 6

X 8

X 10

-

+

E nte r

R ea dy

E rro r

R S

2 32

In pu t

O ut pu t

T es t

C on tr ol

X 9

X 11

V alu e

D IG IT

A L

S ta tus

N um b er

X 6

X 8

X 10

-

+

E nte r

R ea dy

E rro r

R S

2 32

In pu t

O ut pu t

T es t

C on tr ol

X 9

X 11

V alu e

CO M PA X- M

M oti on &

C

o ntr ol

CO M PA X- M

M oti on &

C

o ntr ol

D IG IT

A L

S ta tus

N um b er

X 6

X 8

X 10

-

+

E nte r

R ea dy

E rro r

R S

2 32

In pu t

O ut pu t

T es t

C on tr ol

X 9

X 11

V alu e

cable conduit

L1 L2L3 PE 24V

+ -

24V

+

-

PE

+LS

-LS

U V W PE brake

PE+ -

X1

X2

X3

X5

X1

X2

X3

X4

X4

U V W PE

PE

+ -

X1

1

2

3

4

5

bl

ac

k 1

bl

ac

k 2

bl

ac

k 3

gr

een/

ye

ll

ow

fr

ee

bl

ac

k 4

bl

ac

k 5

brake

Note the screened connection of the motor cable on the
upper unit side.
Clamp the motor cable with the open place of the screen
braid under the ground terminal (see figure on the right).

Only wire up brake in motors which have a holding brake! If not, do not
wire.

The mains supply and the control voltage supply are provided by the mains
module.

Power supply:

!

3*80V AC – max. 3*500V AC; 45 - 65Hz

!

Fuse protection:
NMD10: 16A (K circuit breaker in 20A)
NMD20: 35A
K circuit breaker or similar Neozed
fusible cut-out.

Control voltage

!

24V DC

±

10%

Ripple <1V

SS

Fuse protection: max. 16A

COMPAX-M

Motion & Control

COMPAX-M

Motion & Control

HAUSER

POWER SUPPLY

X6

X7

X8

Ready

E rr or

RS485

IN

OUT

C on tro l

HAUSER

CO MPAX -M

DIGITAL

S ta tu s

Nu m ber

X6

X8

X10

-

+

E nter

Ready

E rr or

RS232

Inp u t

O utp u t

Test

C on tro l

X9

X11

Value

DIGITAL

S ta tu s

Nu m ber

X6

X8

X10

-

+

E nter

Ready

E rr or

RS232

Inp u t

O utp u t

Test

C on tro l

X9

X11

Value

DIGITAL

S ta tu s

Nu m ber

X6

X8

X10

-

+

E nter

Ready

E rr or

RS232

Inp u t

O utp u t

Test

C on tro l

X9

X11

Value

cable conduit

L1 L2L3 PE 24V

+ -

24V

+

-

PE

+LS

-LS

U V W PE brake

PE + -

X1

X2

X3

X5

X1

X2

X3

X4

X4

power supply
module

L1 L2 L3 PE

+ -

X1

1

2

3

4

5

24V

Wiring up the
motor

Screened

connection

Wiring up mains
power / control
voltage