Compax parameter – Parker Products COMPAX-M /-S (L) User Manual

Page 217

background image

COMPAX parameter

217

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error List:

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P112 Slip frequency

A

mHz

100

20 000

VC

Maximum speed

A,S

P113

Linear motor:

126

60000

1000

=

113

P

V

P

max

L

min

-1

0

9000

VC

P115 Angular speed

A

% of
P104

50

100

200

VC

P116 Stator resistance

A,S,L mOh

m

0

150 000

VC

P119 Start of saturation

S,L

%

70

100

VC

P120 End of saturation

S,L

%

> P119

400

400

VC

P121 Minimum stator inductivity

S,L

% of
P109

10

100

100

VC

P122 Main inductivity

A

µ

H

0

2 000 000

VC

P123 Rotor – scatter inductivity

A

µ

H

0

200 000

VC

P124 Rotor resistance

A

mOhm

0

10 000

VC

P125 Nominal voltage

A

V

10

400

VC

P126 Pitch length of motor magnets in

µ

m (2

* Pole distance)

L

20 000

100 000

VC

P127 Denominator: Dash count linear

encoder per pitch length (see P133)

L

-

0

1

VC

P128 Cut-off value of temperature sensor for

E48

A,S,L

0

0

20 000

VC

"0":

HDX / HDY – motors

"1270": HJ – motors

P129 Resolver offset

A,S,L

Degree

0

0

360

VC

P130 Resolver frequency

A,S,L "2":5kHz(P4)

VC

Resolver – transformation ratio

58

A,S,L "2": ü = 0.5 (e.g. P4 resolver)

%

70

100

200

P131

Level adaptation (1/ü) for resolver or SinCos

-

sensor (from V5.61)

setting aids:59

100%

0.5; 200%

0.25; 70%

0.71;

VC

Position sensor

A,S

"2": 2-pol. resolver (P4)

P132

With linear motors:

L

"10": TTL linear encoder
"11": SinCos linear encoder

VC

Sensor dash count

A,S

-

65 536

P133

With linear motors: Dash count linear
encoder per pitch length (counter: see
P127)
Dash count per pitch length =
P133/P127

60

L

1/

µ

m

> P127

<
8388607

VC

P134 Nominal load capacity of the external ballast

resistance (100

) in [W]

Watts

2

60

8000

VC

P135 – P142 Bus – parameter
P143 Encoder pulses per revolution (channel 1)

128

4096

2 000 000

VC

58 Resolver transformation ratio = ü = resolver output voltage / resolver input voltage
59

The read-in level is displayed in the square of the channel 57 optimizing display.
With P233=57 this value is in S13. Meaning:

P131=

%

S

.

100

13

405

0

(rounded to the nearest percent)

The current default setting "2" is still possible.

Note:

Resolver with Ü=1 cannot be operated!

60 Select P133 as large as possible to achieve maximum accuracy. P133 does not have fractional digits.