Compax parameter – Parker Products COMPAX-M /-S (L) User Manual
Page 221
COMPAX parameter
221
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error List:
No.
Meaning
Unit
Minimum
value
Default
value
Maximum
value
Valid
from...
P243 HEDA operation
mode
="0": single axis (when P250=0) or slave on IPM (P250=1 ... 9)
="1": COMPAX as master ="2": COMPAX as slave on a COMPAX master
VP
P245 Assign outputs O1
- O8 to the HEDA
bus
Output (valency) [Bit No]:
O1 (1) [1]
••••
O2 (2) [2]
••••
O3 (4) [3]
••••
O4 (8) [4]
O5 (16) [5]
••••
O6 (32) [6]
••••
O7 (64) [7]
••••
O8 (128) [8]
P245 = sum of valencies of the outputs allocated to the HEDA bus
immedia-
tely
P246 Assign outputs O9
- O16 to the HEDA
bus
Output (valency) [Bit No]:
O9 (1) [1]
••••
O10 (2) [2]
••••
O11 (4) [3]
••••
O12 (8) [4]
O13 (16)[5]
••••
O14 (32)[6]
••••
O15 (64)[7]
••••
O16 (128) [8]
P246 = sum of valencies of the outputs allocated to the HEDA bus
immedia-
tely
P247 - P250
HEDA parameter
VP