Using the parameters P76 and P77, you can select 2 parameters and adapt them
to the required measuring range.

Channel 2: X11/4;

X17/1 for COMPAX 1000SL

6

Channel 3: X11/5;

X17/2 for COMPAX 1000SL

No.

Parameter

Range

P76
Value before decimal p.

Measuring parameter of channel 2.
(see below for meaning).

0...18

P76
Value after decimal point

7

Gain factor from channel 2.
(factor = value * 10 000 000)

0.1... 10 000 000

P77
Value before decimal p.

Measuring parameter of channel 3.
(see below for meaning).

0...18

P77
Value after decimal point

Gain factor from channel 3.
(factor = value * 10 000 000)

0.1... 10 000 000

The parameters can only be actuated once you have entered the password.
They are validated using VP.

Service D/A monitor:

Selection of measuring parameter using P76 / P77

D/A monitor (option D1): Selection of measuring parameter using P73 / P74

Measuring

parameter No.

Measuring parameter

Reference value

8

0

Nominal speed value sensor

20 000 min

-1

1

Tracking error

128›

Motor revolutions

2

Advance speed control

20 000 min

-1

3

Nominal speed value of position controller

20 000 min

-1

4

Actual speed value

20 000 min

-1

5

Speed deviation

20 000 min

-1

6

Not assigned

7

Not assigned

8

Nom. value of transverse current (torque)

9

200A

9

Intermediate circuit voltage

1000V

10

Sine for co-ordinate transformation

11

Voltage positioning signal for phase U

2 * U

LS

12

Voltage positioning signal for phase V

2 * U

LS

13

Phase current for phase U

200A

14

Phase current for phase V

200A

15

Actual value of transverse current (torque)

10

200A

16

Longitudinal current

200A

17

Scaled transverse voltage
(For amplification of 1 use: 10V = 2 * U

LS

)

2 * U

LS

18

Scaled longitudinal voltage
(For amplification of 1 use: 10V = 2 * U

LS

)

2 * U

LS

You will find additional measuring parameters on Page 210!

6

The initiator signals are looped through the monitor box ASS1/01.

7

.0000001=factor 1

.000001=factor 10
.999999=factor 10 000 000

8

Physical value with 10V output voltage and an amplification of 1

9

To determine torque:
torque = transverse current * 0.71 * total torque constant

10

To determine torque:

torque = transverse current * 0.71 * total torque constant

Assignment of the

channels

Meaning and
range of values of
P76 / P77

D/A monitor
standard
measuring
parameters