Appendix, Compax-m/s – Parker Products COMPAX-M /-S (L) User Manual

Page 218

background image

Appendix

COMPAX-M/S

COMPAX standard parameters

218

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P144 Settting encoder channel 1

="4": without external position

localization

="6": external position localization

switched on via channel 1.

VC

P146 Resolution of encoder emulation (channel 2)

=0: 1024

=8: 512

VC

P148 End stage designation

"Read only" – parameter

S37

P149 Configuration

"0": not valid

"1": valid

61

VC

P151 Responsiveness of the monitor control

%

0

30

500

VP

P156 Allocation of inputs I1...I6 to the input pins on

X19

Source for

Bit 0 – 3 input 1
Bit 4 – 7 input 2
Bit 8 – 11input 3
Bit 12 – 15 input 4
Bit 16 – 19 input 5
Bit 20 – 23 input 6

Bits

-8388608

X19/2

I1

X19/3

I2

X19/4

I3

X19/5

I4

X19/6

I5

X19/7

I6

= 7 754 802

8388607

VP

P157 Allocation of inputs I7...I12 to the input pins on

X19

Source for

Bit 0 – 3 input 7
Bit 4 – 7 input 8
Bit 8 – 11input 9
Bit 12 – 15 input 10
Bit 16 – 19 input 11
Bit 20 – 23 input 12

Bits

-8388608

X19/8

I12

I7 ... I11 = "0"

=

-8 388 608

8388607

VP

P158 Allocation of inputs I13...I16 to the input pins on

X19

Source for

Bit 0 – 3 input 13
Bit 4 – 7 input 14
Bit 8 – 11input 15
Bit 12 – 15 input 16
Bit 16 – 19 free
Bit 20 – 23 free

Bits

-8388608

X19/9

I16

I13...I15 ="0"

= 36 864

8388607

VP

P159 Allocation of output pins X19/15 ... X19/18 to

the logic outputs

Source for

Bit 0 – 3 Pin X19/15
Bit 4 – 7 Pin X19/16
Bit 8 – 11Pin X19/17
Bit 12 – 15 Pin X19/18

Bits

0

O1

X19/15

O2

X19/16

O3

X19/17

O4

X19/18

= 12 816

65535

VP

P160 Allocation of output pins X19/19 ... X19/22 to

the logic outputs

Source for

Bit 0 – 3 Pin X19/19
Bit 4 – 7 Pin X19/20
Bit 8 – 11Pin X19/21
Bit 12 – 15 Pin X19/22

Bits

0

O5

X19/19

O6

X19/20

O7

X19/21

O8

X19/22

= 30 292

65535

VP

P161 Maximum angle difference with absolute resolver

function
(4096 = 1 motor revolution)

1

100

2047

VP

P181 HEDA – parameter: coupling window (

µ

m or

increments)

0

10

4 000 000

VP

P182 Setting status monitor S15

0

0

532 767

VP

61 When P149="0", all parameters apart from the bus settings P194, P195, P196, P250 are set to default values when switched on.