Far end line statistics—current, Time elapsed (dsx1farendtimeelapsed), Errored seconds (dsx1farendcurrentess) – Patton electronic 3120 User Manual
Page 280: Severely errored seconds (dsx1farend currentsess), Unavailable seconds (dsx1farendcurrentuass), Controlled slip seconds (dsx1farendcurrentcsss), Line errored seconds (dsx1farendcurrentless)

22 • T1/E1 Link
Model 3120 RAS Administrators’ Reference Guide
280
Far End Line Statistics—Current
Far End Line Statistics—Current
Click on Near End Line Statistics—Current to display far-end statistics for the current 15-minute interval (96
previous intervals will be shown unless the remote access server has been reinitialized in the last 24 hours). See
figure 114).
Figure 114. Current Far End Performance window
Time Elapsed (dsx1FarEndTimeElapsed)
The number of seconds that have elapsed since the beginning of the far-end current error-measurement period.
Errored Seconds (dsx1FarEndCurrentESs)
The number of far-end errored seconds encountered by a DS1 interface in the current 15-minute interval.
Severely Errored Seconds (dsx1FarEnd CurrentSESs)
The number of far-end severely errored seconds encountered by a DS1 interface in the current 15-minute
interval.
Severely Errored Frame Seconds (dsx1FarEndCurrentSEFSs)
The number of far-end severely errored framing seconds encountered by a DS1 interface in the current 15-
minute interval.
Unavailable Seconds (dsx1FarEndCurrentUASs)
The number of far-end unavailable seconds encountered by a DS1 interface in the current 15-minute interval.
Controlled Slip Seconds (dsx1FarEndCurrentCSSs)
The number of far-end controlled slip seconds encountered by a DS1 interface in the current 15-minute inter-
val.
Line Errored Seconds (dsx1FarEndCurrentLESs)
The number of far-end line errored seconds encountered by a DS1 interface in the current 15-minute interval