Dc and ac parameters, Table 109. operating conditions (5v devices), Table 110. operating conditions (3v devices) – ST & T UPSD3212C User Manual
Page 133: Table 111. ac signal letter symbols for timing, Table 112. ac signal behavior symbols for timing
133/163
uPSD3212A, uPSD3212C, uPSD3212CV
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 109. Operating Conditions (5V Devices)
Table 110. Operating Conditions (3V Devices)
Table 111. AC Signal Letter Symbols for
Timing
Note: Example: t
AVLX
= Time from Address Valid to ALE Invalid.
Table 112. AC Signal Behavior Symbols for
Timing
Note: Example: t
AVLX
= Time from Address Valid to ALE Invalid.
Symbol
Parameter
Min.
Max.
Unit
V
CC
Supply Voltage
4.5
5.5
V
T
A
Ambient Operating Temperature (Industrial)
–40
85
°C
Ambient Operating Temperature (Commercial)
0
70
°C
Symbol
Parameter
Min.
Max.
Unit
V
CC
Supply Voltage
3.0
3.6
V
T
A
Ambient Operating Temperature (Industrial)
–40
85
°C
Ambient Operating Temperature (Commercial)
0
70
°C
Signal Letters
A
Address
C
Clock
D
Input Data
I
Instruction
L
ALE
N
RESET Input or Output
P
PSEN signal
Q
Output Data
R
RD signal
W
WR signal
B
V
STBY
Output
M
Output Macrocell
Signal Behavior
t
Time
L
Logic Level Low or ALE
H
Logic Level High
V
Valid
X
No Longer a Valid Logic Level
Z
Float
PW
Pulse Width