beautypg.com

Dc and ac parameters, Table 109. operating conditions (5v devices), Table 110. operating conditions (3v devices) – ST & T UPSD3212C User Manual

Page 133: Table 111. ac signal letter symbols for timing, Table 112. ac signal behavior symbols for timing

background image

133/163

uPSD3212A, uPSD3212C, uPSD3212CV

DC AND AC PARAMETERS

This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-

ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.

Table 109. Operating Conditions (5V Devices)

Table 110. Operating Conditions (3V Devices)

Table 111. AC Signal Letter Symbols for

Timing

Note: Example: t

AVLX

= Time from Address Valid to ALE Invalid.

Table 112. AC Signal Behavior Symbols for
Timing

Note: Example: t

AVLX

= Time from Address Valid to ALE Invalid.

Symbol

Parameter

Min.

Max.

Unit

V

CC

Supply Voltage

4.5

5.5

V

T

A

Ambient Operating Temperature (Industrial)

–40

85

°C

Ambient Operating Temperature (Commercial)

0

70

°C

Symbol

Parameter

Min.

Max.

Unit

V

CC

Supply Voltage

3.0

3.6

V

T

A

Ambient Operating Temperature (Industrial)

–40

85

°C

Ambient Operating Temperature (Commercial)

0

70

°C

Signal Letters

A

Address

C

Clock

D

Input Data

I

Instruction

L

ALE

N

RESET Input or Output

P

PSEN signal

Q

Output Data

R

RD signal

W

WR signal

B

V

STBY

Output

M

Output Macrocell

Signal Behavior

t

Time

L

Logic Level Low or ALE

H

Logic Level High

V

Valid

X

No Longer a Valid Logic Level

Z

Float

PW

Pulse Width

This manual is related to the following products: