beautypg.com

Siemens Automation System S7-400 User Manual

Page 114

background image

Networking

5-16

Automation System S7-400 Hardware and Installation

A5E00850741-01

Lengths of Spur Lines

If you do not fit the bus cable directly at the bus connector (for example, when
using a PROFIBUS-DP bus terminal), you must take into account the maximum
possible spur line length.

The following table gives the maximum lengths of spur lines allowed per bus
segment:

Table 5-3

Lengths of Spur Lines per Segment

Transmission Rate Maximum

Length of a

S

Li

Number of Nodes per

Spur Line Length of ...

Maximum

Length of

S

Li

g

Spur Line

1.5 m and

1.6 m

3 m

g

Spur Lines

per Segment

9.6 to 93.75 kbps

3 m

32

32

96 m

187.5 kbps

3 m

32

25

75 m

500 kbps

3 m

20

10

30 m

1.5 Mbps

3 m

6

3

10 m

A spur line is not permissible with transmission rates greater than 1.5 Mbps.

To connect a programming device or PC, use the connecting cable for the
programming with theorder number 6ES7901-4BD00-0XA0. You can use several
connecting cable with this order number for programming devices in one bus
configuration.