beautypg.com

Intel IXF1104 User Manual

Page 217

background image

Intel

®

IXF1104 4-Port Gigabit Ethernet Media Access Controller

217

Datasheet

Document Number: 278757

Revision Number: 009

Revision Date: 27-Oct-2005

15

Rx_parity_sense Port 3

SPHY Mode:

Indicates the parity sense to check the parity on
RDAT bus for port 3.

0 = Odd Parity
1 = Even Parity

MPHY Mode:

NA

R/W

0x0

14

Rx_parity_sense Port 2

SPHY Mode:

Indicates the parity sense to check the parity on
RDAT bus for port 2.

0 = Odd Parity
1 = Even Parity

MPHY Mode:

NA

R/W

0x0

13

Rx_parity_sense Port 1

SPHY Mode:

Indicates the parity sense to check the parity on
RDAT bus for port 1.

0 = Odd Parity
1 = Even Parity

MPHY Mode:

NA

R/W

0x0

12

Rx_parity_sense Port 0

SPHY Mode:

Indicates the parity sense to check the parity on
RDAT bus for port 0.

0 = Odd Parity
1 = Even Parity

MPHY Mode:

Indicates the parity sense to check the parity on
RDAT bus for all ports.

0 = Odd Parity
1 = Even Parity

R/W

0x0

11

Rx_port_enable
Port 3

SPHY Mode:

0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.

MPHY Mode:

0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.

R/W

0x1

10

Rx_port_enable
Port 2

SPHY Mode:

0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.

MPHY Mode:

0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.

R/W

0x1

Table 147. SPI3 Receive Configuration ($0x701) (Continued) (Sheet 3 of 4)

Bit

Name

Description

Type

1

Default

1. RO = Read Only, No clear on Read; R = Read, Clear on Read; W = Write only; R/W = Read/Write, No

clear; R/W/C = Read/Write, Clear on Write