Point – FUJITSU ServerView Respurce Orchestrator Virtual Edition V3.1.0 User Manual
Page 163

[Power off forced when the server is switched over] checkbox
Check this checkbox if the spare server is to be turned off forcibly when the spare server in started before switchover takes place.
When shutting down the spare server, clear this checkbox.
This option is not selected by default.
[Switchover to server where VM guest exists] checkbox
When a spare server is a VM host, check this checkbox if switching to a spare server in which the VM host contains a VM guest.
When not switching to a VM host which contains a VM guest, clear this checkbox.
This option is not selected by default.
3.
Click
The server switchover settings are configured.
4.
Set the boot agent for the spare server.
If the Windows manager is used and the primary server is in a configuration with a local boot environment, execute the following
command on all servers that have been set as spare servers.
-
In a SAN data environment using a physical WWN or VIOM
[Windows Manager]
>
Installation_folder
\SVROR\Manager\bin\rcxadm server set -name
physical server
-attr bootagt=dos
[Linux Manager]
#/opt/FJSVrcvmr/bin/rcxadm server set -name
physical server
-attr bootagt=dos
-
When using the Red Hat Enterprise Linux 6 ext4 file system, and one of the following conditions is met
-
In a SAN boot environment using HBA address rename
-
When using a rack mount or tower server and the server is registered with "Disable" of "Association with server management
software (ServerView)" is selected
[Windows Manager]
>
Installation_folder
\SVROR\Manager\bin\rcxadm server set -name
physical server
-attr bootagt=winpe
[Linux Manager]
#/opt/FJSVrcvmr/bin/rcxadm server set -name
physical server
-attr bootagt=winpe
-
In a SAN boot environment using HBA address rename, and the following model
-
PRIMERGY BX960 S1
[Windows Manager]
>
Installation_folder
\SVROR\Manager\bin\rcxadm server set -name
physical server
-attr bootagt=winpe
[Linux Manager]
#/opt/FJSVrcvmr/bin/rcxadm server set -name
physical server
-attr bootagt=winpe
Point
The conditions specified in "9.3 Server Switchover Conditions" in the "Setup Guide VE" must be satisfied for server switchover to be
executed correctly.
Once settings are complete, perform switchover and failback on each spare server that has been set up to verify that these operations can
be executed correctly.
A function to check the server operations after auto-recovery has been activated (by causing a dummy failure to occur) is not provided
- 148 -