Sensor Installation and Connection

3-31

MAX ROTATION OFF

BOTTOM CENTER

OF

PIPE

CENTER

15°

15°

REQUIRES

SILT MOUNT ADAPTER

45°

Rotating the Peak Combo Sensor no more than 15 degrees up either side of

the pipe (between the 5:30 and 6:30 positions) or between 15 and 45

degrees up the left side of the pipe (6:30 to 7:30 position) with the silt mount

adaptor

 If necessary, temporarily clear away silt to install the ring.

Restore the silt after fully securing the ring (step 7).

 Make sure the ring is flat (flush) against the inside surface

of the pipe to avoid obstructing the flow or catching debris.

 Verify that the Peak Combo Sensor or silt mount adapter

(when applicable) is flush with the pipe surface. Any
elevation of the sensor or significant deterioration or
imperfection in the pipe surface around the sensor can
create an open space in which debris can become trapped.
An elevated sensor also can misdirect the signal when
taking measurements. These vulnerabilities can quickly
result in potential damage or disruption to the sensor
and/or erroneous data.