Xio (ads p/n 8000-0400) – ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual
Page 395

A-14
ADS TRITON+ Manual
XIO (ADS p/n 8000-0400)
The XIO
™
(External Input/Output unit) enables the TRITON+ to
receive power from an AC power source and serves as a digital and
analog input and output interface.
Enclosure
Indoor/outdoor NEMA 4X (IP 66), PBT and
polycarbonate plastic with hinged cover
Dimensions
11.02 inches (280 mm) long x 7.49 inches (190
mm) wide x 5.03 inches (128 mm) deep
Weight
5.0 pounds (2.3 kg)
Operating/
Storage
Temperature
14
° to 122° F (-10° to 50° C)
Power Supply
XP Power DNR60US24 (Refer to page A-12 for
specifications and details on the power supply)
Power Input
85-264 VAC, 120-375 VDC; 47-63 Hz; 1.10 A @
110 / 0.59 A @ 250 VAC
Analog Inputs
Two 4-20mA inputs
Isolation: 1500 VAC
Accuracy: 0.05% F.S.
Thermal Drift: 100ppm/C
Analog Outputs
Two 4-20mA outputs
Provides loop power
500 ohm drive capability
Isolation: 1500 VAC
Accuracy: 0.1% F.S.
Linearity: 0.05% F.S.
Thermal Drift: 100ppm/C