8-12

ADS TRITON+ Manual

 Click on the OK button on the XIO Device dialog.

 Activate the monitor. Refer to Chapter 6, Configuration

and Activation, for instructions on activating the monitor.

 Disconnect from the monitor.

 Contact the customer representative to verify the receiving

instrument is producing the same value.

 Upon confirmation, return to the XIO Device dialog in

Qstart, deselect the Enable Manual checkbox(es), and
click on the OK button.

7. Re-activate the monitor.