ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual
Page 280

7-6
ADS TRITON+ Manual
Note: ADS strongly recommends attaching a security line
to the monitor before lowering it into the manhole to
prevent the monitor from accidentally dropping down the
manhole during installation.
7. Tighten and secure the bolt against the mounting bracket.
Monitor installed in the manhole
8. Neatly coil and secure the excess sensor and communication
cables in the manhole to simplify future monitor service
activities. Secure the cables to plastic anchors or ¼-inch x 2¼-
inch (M6 x 55-mm) anchor bolts using 14-inch.(5-mm x 300-
mm) cable ties.
Note: Be careful to avoid damaging the sensor cables
during installation activities. Even small pinholes in the
cable can cause a sensor to malfunction or fail.