beautypg.com

ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 86

background image

Sensor Installation and Connection

3-25

Mounting the Peak Combo Sensor

Mount the Peak Combo Sensor to the ring in the following way:

1. Use two M3 X 10mm stainless steel flathead screws (do not

substitute any other screws) to attach the sensor at the bottom
of the ring (opposite the Surface Combo Sensor/Ultrasonic
Depth Sensor) or up to 15 degrees up either side of the pipe
(5:30 to 6:30 position) with the blunt end (i.e., nose) of the
sensor facing upstream.

Mounting the Peak Combo Sensor to the ring

If the installation requires the use of a silt mount adapter (ADS
p/n 8000-0271) to install the sensor further up the left side of
the pipe (between 15 and 45 degrees, or the 6:30 to 7:30
position
), attach the Peak Combo Sensor to the ring in the
following way:

 Seat the Peak Combo Sensor onto the slightly elevated

portion of the top of the silt mount adapter. The elevated
portion of the adapter should insert easily into the inset
portion of the bottom of the sensor. Orient the sensor so
that the sensor cable is exiting the sharp, or wedged, side
of the adapter.

 From the bottom of the adapter, use two M3 X 10mm

stainless steel flathead screws (do not substitute any other
screws
) to secure the sensor to the adapter. The pre-drilled
screw holes in the adapter and in the bottom of the sensor