Removing the carriage (yćaxis) motor – HP 750 User Manual
Page 76
1 Remove the electronicsĆenclosure
cover ' page 6Ć5.
2 Remove the window ' page 6Ć13.
3 Remove the centercover' page 6Ć14.
4 Remove the right endcover ' page 6Ć17.
5 Disconnect the carriageĆmotor cable from
the main PCA (connectorlabelled Y).
6 Remove the two screws that attach the carriageĆmotor to the structure. Hold the
motorin a secure position.
Y-Carriage
motor
Reassembling: Position
the YĆaxis drive belt before
positioning the screws, and
ensure that the belt is
correctly positioned around
the carriageĆmotor gear
and the lower part of the
pulley.
Tx 15
6-24
Removal and Replacement
C4705-90000
Removing the Carriage (YĆAxis) Motor