beautypg.com

HP 750 User Manual

Page 217

background image

C4705-90000

10-19

Product History and Service Notes

3 SwitchĆon the device.
4 Open the window cover and verify that the mark encoder is in the upper position on the

right side of the roller platen. If the mark encoder is not in the upper position, then

perform the Mark Position test ' page 8Ć44.

5 Clean the mark encoder using the cleaning wipes Ć HP 92193N. These wipes contain

isopropyl alcohol. Allow a few seconds to ensure that the mark is dry.

6 Get a sheet containing the black adhesives lines. Identify the adhesive side (you may test

it on a piece of paper).

7 Trim a piece of the sheet containing one black line.
8 Place the line in the center of the mark encoder, positioning it parallel to the platen

roller.

9 Using a pen, softly rub on the back of the line.

10 Make sure that the:

D Line is properly stuck on the contact surface of the mark encoder
D Line is continuous and not broken.

11 If this is not the case, remove the line with a tool that can not damage the mark encoder

and clean it again using the cleaning wipes. Then repeat the procedure from step 6.

12 Using matte film media, perform the accuracy calibration ' page 7Ć6.

Administrative Information

Classification:

Modification Recommended

Standards:

0.5 Hour Labor

Action Category:

On Failure

Location Category:

OnĆSite

Service Inventory:

N/A

Used Parts:

N/A

HP Responsible Until: 1 February 1998
Author Entity:

EV/F900