beautypg.com

HP 750 User Manual

Page 161

background image

Troubleshooting

C4705-90000

8-43

22. X Motion Control

The purpose of this test is to determine the power required to move the drive roller.
Perform the X motion control test as follows:

1 In the Service Tests submenu, scroll to 22 X Motion Control" and press Enter.

SERVICE TESTS

22 X Motion control

2 The Remove Media / Press Enter" message is displayed on the frontĆpanel. Remove the

media (if loaded) and press Enter to start the test.

3 The Faster / Slower" message is displayed on the frontĆpanel. Use the Up Arrow to

increase the speed of the drive roller and the Down Arrow to decrease the speed of the

drive roller.

4 Press the Enter button.
5 The X Max PWM = # / Press Enter" message is displayed on the frontĆpanel.

If the maximum value (#) of

X Max PWM is less than 100 then the test has passed.

If the maximum value (#) of

X Max PWM is more than 100 then the test has failed.

If the test fails, try replacing one of the following components:

1 XĆaxis motor ' page 6Ć25.
2 Main PCA ' page 6Ć9.

Only replace one component at a time and perform the “X Motion Control” test again before
replacing another component. Using this procedure you will be able to determine exactly which
component failed.