Troubleshooting

C4705-90000

8-21

1. EEROM

The purpose of this test is to clear or test the EEROM. It will test the:

D EEROM.
D Main PCA.

The test clears the defaults of all calibration values and calculates a new EEROM checksum.

The EEROM should only be cleared in the event of a checksumfailure.
Performthe EEROM test as follows:

1 In the Service Tests submenu, scroll to 1 EEROM" and press Enter.

SERVICE TESTS

1 EEROM

2 The Clear EEROM / Test EEROM" message is displayed on the frontĆpanel.

3 Press the Down Arrow to test the EEROM.
4 The Testing / Don't Power Off" message is displayed on the frontĆpanel.

5 If the test passes, the Pass Test / Press Enter" message is displayed on the frontĆpanel.

Press Enter to return to the Service Tests submenu.

6 If the test fails, the Fail Test / Press Enter" message is displayed on the frontĆpanel and

you must clear the EEROM as follows:

7 Press Enter to return to the Service Tests submenu and then select the EEROM test.
8 Press the Up Arrow to clear the EEROM.

The EEROM should only be cleared in the event of a checksum failure. Otherwise the

EEROM should never be cleared.
After clearingthe EEROM, switch the plotter OFF and ON again without any media

loaded and perform the followingcalibrations in the order listed:

1 Drop detect calibration ' page 7Ć4.
2 Line sensor calibration ' page 7Ć5.
3 Accuracy calibration ' page 7Ć6.

It is recommended that a configuration plot is printed from the Utilities" menu for

setup reference. You will also need to reconfigure the frontĆpanel settings.