beautypg.com

Choosing a suitable plotter environment – HP 750 User Manual

Page 21

background image

Site Planning and Requirements

C4705-90000

2-3

Choosing a Suitable Plotter Environment

The table below lists the environmental specifications for the plotters.

Environmental Specifications

Temperature

Storage
Operating
Optimal Operating

–40 to +70

_

C (–40 to +158

_

F)

0 to +55

_

C (+32 to +131

_

F)

+15 to +30

_

C (+59 to +86

_

F)

Relative Humidity (Operating)

20 to 80 % RH

Operating environment:

Plotter/Printer

With cartridges and media:

Optimal print quality and media
handling:

Temperature

Relative Humidity

0 to 55

_

C (32 to 131

_

F)

5-95%

15 to 35

_

C (59 to 95

_

F)

20-80%

15 to 30

_

C (59 to 86

_

F)

20-80%

Storage environment:

Plotter/media

Cartridges

Temperature

Relative Humidity

–40 to +70

_

C

(–40 to +158

_

F)

20-80%

–40 to +60

_

C

(–40 to +140

_

F) 20-90%

Acoustics:*

Operating

Idle

Sound Pressure

Sound Power

54 dB (A)

6.5 bels (A)

< 20 dB (A)

< 3.6 bels (A)

*

These specifications are typical sound pressures at a oneĆmeter bystander position. Idle specification

assumes fan is off.

Plotter Dimensions and Weight

Plotter Model:

E/A0-size plotters

D/A1-size plotters

Height (window closed)
Depth
Length

Weight

1200 mm (47.3 in)

1200 mm (47.3 in)

675 mm (26.6 in)

675 mm (26.6 in)

1370 mm (54 in)

1072 mm (42.2 in)

42 kg (93 lbs)

32 kg (71 lbs)