HP 750 User Manual

Page 140

background image

8-22

Troubleshooting

C4705-90000

2. EEROM Clear Counters

The purpose of this test is to reset the counters of the EEROM after periodic preventive

maintenance hasbeen performed.
Clear the EEROM countersasfollows:

1 In the Service Tests submenu, scroll to 2 EEROM Clr countrs" and press Enter.

SERVICE TESTS

2 EEROM Clr countrs

2 The Reset carr. count / Reset plots count" message is displayed on the frontĆpanel.

3 Press the Up Arrow to reset the carriage counter or press the Down Arrow to reset the

plotscounter.

4 If the counters have been reset correctly, the following messages will be displayed on the

frontĆpanel:

D

Carriage cyclescounter reset" if the carriage counter isreset.

D

Plotscounter reset" if the plotscounter isreset.

5 Press Enter if another counter needs to be reset or press Previous if you want to return

to the Service Tests submenu.