8-13
Error Code
Corrective Actions
Problem Description
02002x
Firmware error related in
most cases to the PostScript
process. (x = values 0Ć9 hex)
D Possible defective PostScript SIMM.
Also check that the PostScript SIMM is
installed in the second slot from the top
on the Main PCA.
030010
Excess friction in pen
capping assembly
D Check the sled movement in the service
station, simulating the entering
operation of parking the carriage.
D Replace the service station ' page 6Ć42.
04xxxx
MIO interface error.
D If an MIO is installed, check the MIO
setup. If necessary, replace the MIO.
D Check/replace the main PCA ' page 6Ć9.
040601
The MIO card does not
support the MIO 6 protoc ol.
Cards with version 5 or below
can not be used with this
plotter.
Version 5.1 cards behave as
expected but do not support
PML instructions.
D Install the latest version of the MIO card.
05xxxx
MIO system error.
D Check/replace the main PCA ' page 6Ć9.
06030A
Mark position not found.
D Perform the mark position test ' page
8Ć44.
06030B
Bad ambient temperature
read.
D Replace the cartridges.
D Replace the carriage PCA.
060308
060309
Problem with Pen Voltage
Control.
D Replace the cartridges.
D Replace the carriage PCA.