8-12
Troubleshooting
C4705-90000
Error Code
Corrective Actions
Problem Description
010050
Defective Postscript SIMM.
D Check/replace the Postscript SIMM.
010060
Primer motor/sensor
initializefailure.
D If the primer stepper motor operates,
then check the primer sensor
connection and/or operation. If it does
not operate, replace the:
D
Primer ' page6Ć41.
D
Cableassembly ' page6Ć47.
D
Main PCA ' page6Ć9.
Only replace one component at a
time and check if the error has gone
before replacing another component.
Using this procedure you will be
able to determine exactly which
component failed.
D Make sure that the primer sensor is
correctly positioned.
010080
RSĆ232ĆC data overflow.
D Data bytewas not read beforeanother
was entered into the UART. Check the
handshakesettings in thesoftware
application configuration.
D Replacethemain PCA ' page6Ć9.
D If the problem remains, report the
problem to the HP Response Center or
the nearest HP Support Office.
020001
020002
Memory fragmentation error.
D Turn Queing to OFF in the frontĆpanel.
D Add morememory.
D If the problem remains, report the
problem to the HP Response Center or
the nearest HP Support Office. Note
conditions before the error occurred.
Includesystem configuration in the