8-8

Troubleshooting

C4705-90000

Message

Error/Action

Sheet misaligned
Reload sheet

D Sheet media is skewed. Remove it and reload it so that the right

edge being loaded into the plotter is aligned with the perforated

line on the entry platen. Make sure that the leading edge is

straight.

Switch power off
Check cartridge path

D A servo shutdown has occurred in the YĆaxis. The cartridge

carriage cannot move. The plotter may be jammed with

media. Switch the plotter OFF. Check the pen path, and clear if

necessary.

D If required, troubleshoot the YĆaxis mechanics and circuitry.

Switch power off
Check media path

D A servo shutdown has occurred in the XĆaxis. The drive roller

cannot move, or the roll feed spindle cannot freely rotate. The

plotter may be jammed with media. Switch the plotter OFF.

Check the media path, and clear it if necessary.

D If required, troubleshoot the XĆaxis mechanics and circuitry.

System error

XXXXXX

D An internal error has occurred and a multiĆcharacter

alphaĆnumeric code is displayed. Users should turn the plotter

OFF and then ON again to try to clear the error message.

D The meaning of the error codes is explained on page 8Ć9.

Wrong Cartridge
Type

D You have loaded one or more incompatible cartridges. Replace

the cartridges with those appropriate for this plotter. If the

message continues, then perform the carriage test (details '

page 8Ć27) and the mainĆcarriage comunications test (details '

page 8Ć26).