Calibrations

C4705-90000

7-3

Menu Path

All calibration procedures are accessible through the frontĆpanel menu structure. The

accuracy calibration is available through the Utilities main menu. The service

configuration plot function, also located in the Utilities" menu, is used in conjunction

with the accuracy calibration procedures for comparison purposes. Procedures reserved for

service use are available through the Service Tests" menu, which is a subset of the

Utilities" menu.

Entering the Service Tests Menu System

1 Switch the plotter ON.

Certain plotter failures that can occur will prevent the plotter from reaching the “STATUS /
Ready for Media” state. If one of these problems occurs, switch the plotter OFF. Press and hold
down the ENTER and the UP ARROW buttons while switching the plotter ON. This will allow
access to the service tests.

2 Press the Enter button.
3 Use the Arrow buttons to scroll to the Utilities" menu display. Either the Short or Full

menu mode will access the Service Tests" submenu.

4 Press the Enter button.
5 Simultaneously press the Enter and the Up Arrow buttons to access the

Service Tests" submenu.

6 Use the Arrow buttons to scroll through the test selections.
7 Press the Enter button to begin a specific test when the required test is displayed.

If no button is pressed for 1.5 minutes, the front panel will return to the “Status” menu.

In some cases a quick press of a button may not be recognized by the processor. When pressing a
button, be sure to press it deliberately and all the way to the bottom of its travel.

If the plotter hangs up during a test, switch the plotter OFF and restart at step 1 again.

In some cases the plotter may revert to the “STATUS” message upon exiting a test. To return to
the service menu, perform the above steps.