Troubleshooting

C4705-90000

Service Tests and Error Messages

To aid fault diagnosis, error messages in words and hexaĆdecimal error codes are displayed,

andthere is a full set of Service Tests available on the extensive Service Menu.
This is then followedby Error message/code listings groupedby area of fault to assist in

diagnosis. Within the table facing the Error Messages/Codes, corrective actions are listed.
Service tests and troubleshooting tips relevant to the faulty area are included.
Two types of error messages can be viewedon the frontĆpanel display:

D Worded error messages.
D System error codes.

Worded Error Messages
Worded error messages indicate that a user error or an internal error has occurred. Some

error messages require action to clear, andothers are only displayeduntil the next operation

is performedby the plotter. See the table on page 8Ć5 for an alphabetical listing.

Error Codes
The frontĆpanel displays a sixĆdigit hexaĆdecimal error code, the meanings of which are given

in this Chapter. See the table on page 8Ć9 for a numerical listing of possible error codes.
The following table gives a quick explanation of the error codes:

Error code

Type of Problem

01xxxx

Hardware Failure

02xxxx

Software/Memory Failure

03xxxx

Hardware Problem

04xxxx and05xxxx

MIO System Failure

06xxxx

Pen Alignment System Error

07xxxx

Drop Detect System Error

Service Tests
The plotter has many internal service tests that can be usedin troubleshooting. Instructions

for entering the service tests menu are given on page 8Ć20.